Air exchange area and calculation of fans in a poultry house
Air exchange area m3/minute
= Length
width height
For example
Air exchange area
m3/minute = 120m×12m×03m =4320 m3
Air
exchange area m3/minute =
4320 m3
No. of fan needed for air exchange =
Air volume m3/minute
Air
exchange capacity of Fan
Standards
1. Fan with a diameter of
1.2m = 566 m3/minute
2. Fan with a diameter of 1.0m
= 283 m3/minute
3. Fan with a diameter of 91cm = 255 m3/minute
For example
No. of fan needed for air exchange = Air volume m3/minute ÷ Air exchange capacity of Fan
No. of fan needed for air exchange = 4320 ÷ 566 =7.6 or 8 Fans
No.
of fan needed for air exchange = 08 fans
Calculation of space for Cooling Pad in poultry house(m2) =
(Fan
air exchange Capacity m3/minute × Number of fans)÷ AirSpeed through cooling pad m3/minute
Standards
3. For 100mm (10cm or 4-in) thick Pad,
use ( 1.27m/s or 76m/minute )(250fpm)
use ( 1.27m/s or 76m/minute )(250fpm)
4. For 150mm (15cm or 6-in) thick Pad,
use ( 1.91m/s or 114/minute ) (375fpm)
use ( 1.91m/s or 114/minute ) (375fpm)
For example
Cooling Pad area m2
= (Fan air exchange Capacity m3/minute × No. of fans)÷ (Air Speed through cooling pad m3/minute)
= (Fan air exchange Capacity m3/minute × No. of fans)÷ (Air Speed through cooling pad m3/minute)
Cooling
Pad area = (566 × 8 )÷114 = 39.7m2 Or
40m2
*It means
20m2 (2m in width and 10 m in length) on each side of the
house
Cooling Pad area in m2 = 40m2
The number of fans Needed to exchange required air velocity
=(Required
Air velocity m/s ) ÷{ Fan capacity ÷ (width × Height ×60) }
Standard
Air velocity
Rearing ˃ 2.03 meters per second (m/s) OR 400 Feet per minute
(fpm)
Production ˃ 2.54 meters per second (m/s) OR 500
Feet per minute (fpm)
For
example
The number of fans Needed to exchange required
air velocity =
(Required Air velocity m/s ) ÷{ Fan capacity ÷ (width × Height ×60) }
No. of fans Needed to exchange required air
velocity =(2.03) ÷ { 566 ÷(12×03×60} =7.8 fans
No. of fans Needed to
exchange required air velocity = Fans 8
Minimum Ventilation Calculation For Fan Timer Setting
Standards
Minimum ventilation per bird
Age
|
Cubic meter per
hour
(CMH/Bird)
|
Cubic feet per
minute
(CFM/Bird)
|
01-08 weeks
|
0.16
|
0.10
|
09-15 weeks
|
0.42
|
0.25
|
16-35 weeks
|
0.59
|
0.35
|
35- depletion
|
0.76
|
0.45
|
For example
Bird Age = 20 weeks
Number of Birds = 10,000
Minimum ventilation fan = 1 × 91
cm =255 m3/minute × 60 =( 15300m3/hr )
Using a 5 minutes cycle timer
Calculate the minimum
Ventilation?
Step:1
Ventilation rate = (Minimum ventilation per bird) ×( Number of Birds)
Ventilation rate= (0.59 cmh) ×(10,000)
= 5,900 cmh (cubic meter per hours)
Percentage time the fans needed to be run for
Step:2
Percentage time =
(Total ventilation needed) ÷ (Total capacity of fans used)
Percentage time
=(5,900cmh) ÷ (15,300) =0.39 or 39%
Percentage
time =39%
*It
means if a 5-minute timer is used, the run timer required would be then 39%
of 5 minutes or 117 seconds
( or the fan should be 24 sec on and 36 sec off for each minute)
For example
Bird Age = 01 weeks
Number of Birds = 10,000
Minimum ventilation fan = 1 × 91 cm =255 m3/minute × 60 =( 15300m3/hr )
Using a 5 minutes cycle timer
Calculate the minimum Ventilation?
Step:1
Ventilation rate = (Minimum ventilation per bird) ×( Number of Birds)
Ventilation rate= (0.16 cmh) ×(10,000) = 1600 cmh (cubic meter per houre)
Percentage time the fans needed to be run for
Step:2
Percentage time = (Total ventilation needed) ÷ (Total capacity of fans used)
Percentage time =(1600cmh) ÷ (15,300) =0.10 or 10%
Percentage time =10%
*Assuming a 05-minute cycle timer, the run Timer required would then be 10 % of
05 minutes or 30 seconds
36 comments:
MA SHA ALLAH DR.SAHIB GOOD WORK, KEEP IT UP.
THANKS DR. SAHIB
Realy good work for new commers.
VERY GOOD
Thanks Sir,Dr.Habib-ur-Rehman for complements.
excellent
Thanks Respected Dr Majid Gilani sahib
i didnt understand anything
Read it again carefully
Read it again carefully
Very Good work
I have one question about the length of the cooling pad in each side of the house.
Do we have maximum or minimum length we have to follow ?
if the house is 100 meter long for example. Is there is a limitation of length of cooling pad ( not more than 30% of the house length ).
Thanks for your reply in advance.
Motasam Ezelarab, Egypt
masha ALLAH dr sahib can i have your contact no.
thanks 00966500328111
What are the minimum ventilation rates for cage layer. If have any information box me.
dr.habib@gmail.com
What are the minimum ventilation rates for cage layer. If have any information box me.
malik_naveed001@yahoo.com
https://www.poultryventilation.com/sites/default/files/presentations/winnepeg.pdf
Please give me in calculation of ventilation for Pullet and Layer Houses considering temperature of 45 degree Celsius. email address ssidana@mail.com
Very strange question in modern poultry the normal temperature is 18-24 Celsius for Pullet and Layer.At 45 degree Celsius very hard for chicken to survive .
how does the housing pressure affect in choosing Fan for poultry?
because at different pressure, we have different volume capacity?
i dont see any formula mentioning about noticing the pressure.
thanks very much
I have only 4 question: how we can calculate fresh air for 1000 pullet in one hour? how much Co2 produced by 1000 layer in one hour? how much oxygen required for one layer in one hour? and how much Co2 can kill a layer? thank in advance
this is my email address: nooralam.fayzan59@gmail.com
Dr sahib i need calculation for open sided structure
A Very good clarification
Very good work. Sir is there any information about broiler management if yess then please tell me the link. Thanx
There is a broiler management guide. You can download it
kindly share me the link for broiler management guide at drwaqas34@gmail.com
Please send this me at my email address
Sir how we calculate Cfm
Sir ur id mail plz
Nice Blog Thank you for Sharing information. For Poultry Environment Controller Equipment's in India visit Vijay Raj Poultry .
what is the standard requirement of layer breeder bird in hot weather in cfm/bird in possitive air pressure house.and how much possitive presser we mainten for good production
Whewre you get yours below given values?
& What is this?
1. Fan with diameter of 1.2m = 566 m3/minute
2. Fan with diameter of 1.0m = 283 m3/minute
3. Fan with diameter of 91 cm= 255 m3/minute
Others things I have to understand but what is above valus
Kindly reply
Nice Blog Thank you for sharing information about poultry products. To Buy Cooling Pads for Poultry Houses visit Vijay Raj Poultry Equipments Pvt Ltd.
Thank you for sharing information about poultry maintenance in your blog. To Buy Poultry Environment Controller Equipment’s at Best Price in India Visit Vijay Raj Poultry Equipments Pvt Ltd.
excellent work
She is considering out side temperature
thanks
Post a Comment